117632-1   Basement Substations Typical Fan and Damper General Arrangement

117633-1   Basement Substations Exhaust Fan Damper Details

227355-2   RMICB Substations with E Type LV Board and Optical Arc Flash Detection Cable Schedule

227379-1   Distribution Substation with Optical Arc Flash Protection. Terminal Box Details for 48V ‘B’ Battery System

227380-1   City Distribution Substations with E Type LV Board and Optical Arc Flash Detection AC Schematic

227380-2   City Distribution Substations with E Type LV Board and Optical Arc Flash Detection Transformer DC Schematic

227380-3   City Distribution Substation with E Type LV Board and Optical Arc Flash Detection Customer Overcurrent  DC Schematic

227380-4   City Distribution Sub with E Type LV Board and Optical Arc Flash Detection DLAC Panel Schematic, General DC Supplies Inter-Panel Wiring, Fibre Comms and  Cabling Diagram

227380-5   City Control Point Scada Panel Schematic, General DC Supplies, Inter-Panel wiring, Comms & Cabling Diagram

227380-6   City Control Point Scada Panel Wiring Diagram

227381-1   City Distribution Centres with E Type LV Board and Optical Arc Flash Detection Transformer/Customer Overcurrent Protection Panel Layout Details

227382-1   City Distribution Centres with E Type LV Board with Optical Arc Flash Detection Transformers and Customers Overcurrent Free Standing Panel Label Details

227383-1   City Distribution Centres with E Type LV Board, Dry Type TX, and Optical Arc Flash Detection Transformer Protection Panel Wiring Diagram

227383-2   City Distribution Substations with E Type LV Board and Oil Type TX and  Optical Arc Flash Detection Transformer Protection Panel Wiring Diagram

227384-1   City Distribution Centres with E Type LV Board and Optical Arc Flash Detection Protection Transformer Panel Cable Connection Diagram

227384-2   City Distribution Centres with E Type LV Board and Optical Arc Flash Detection Protection Transformer Panel Cable Connection Diagram

227385-1   City Distribution Substations with E Type LV Board and Optical Arc Flash Detection Customer OC No.1(&No.2) Protection Panel Wiring & Cable Connections

227386-1   City Distribution Substations with E Type LV Board and Optical Arc Flash Detection Protection Cabling Diagram

227386-2   City Distribution Substations with OAFD - Cable and Inter-Panel Wiring Schedule

227386-3   City Distribution Substations (High Level) with E Type LV Board and Optical Arc Flash Detection Cabling Diagram

227387-1   City Distribution Substations with E Type LV Board, Optical Arc Flash Detection, and 1500KVA Transformers Service Board Layout, Wiring & Cabling

227388-1   City Distribution  Substations with E Type LV Board and OAFD  Distribution Local Automation Control Panel Layout & Label Details

227388-2   City Control Point Scada Panel with SEL-2240 Axion Layout & Label Details

242607-1   HVC Kiosk and Chamber Substations Earthing Schematic

244218-1   RMICB Substations with Optical Arc Flash Protection. Preferred layout of Batteries, Battery Chargers and SCADA.

43140-1     Distribution substations details of standard louvred doors

48009-1     Distribution substations details of standard weatherproof louvred and guide vane panels for ventilation ducts

48849-1     Multi-blade Fire Damper Details.

53680-1     Basement chambers louvre size selection table

117634-1   Basement chambers C02 pipework, brackets and tripwire details

117635-1   Basement chambers C02 items 1, 3 and 9 details

184970-1   Basement chambers fire protection C02 pipework and tripwire typical arrangement and details

1856-1   City Distribution Substations Details of Signal System Disconnection Box

2064-1   Basement Substation Chamber CO2 connection Union & CO2 Nozzle Detail

10578-1   Sydney CBD Type Substations & Control Points Isolating Switch Operating Wheel for Pull-Out Gear Arrangement & Details

10635-1   Distribution Substations Wall Mounted Double Tier Supporting Frame For Tripping Batteries

16500-1   Sydney CBD Type Substations & Control Points Emergency Pull-Out Gear Operating Equipment Typical Arrangement.

18894-1   Sydney CBD Type Substations & Control Points Emergency Pull-Out Gear Operating Equipment Arrangement & Details

22212-1   Tripping Battery Test Box Assembly & Wiring Details

25121-1   Substation Earthing Typical Installation of Earthing Electrodes

28632-1   Wall Mounted Relay Panels Details

28949-1   Personnel and Equipment Hatch Installation

31858-1   Substations Operators Locker

42416-1   Basement Substation Fan Mounting Plate (*Sydney CBD Substation only)

48008-1   Standard Substation Design Construction Details Miscellaneous               

48546-1   Low Voltage Transformer Termination Shroud for 750kVA, 1000kVA and 1500kVA Oil Filled Transformers Arrangement and Details

50740-1   Transformer Hatchcover and Rebate

507111-1   Moulded Type Link Assembly

50996-2   Moulded Type M5 Links 5C1 TO 5C14 Label & Drilling Details

64825-1   Moulded Type M5 Link Assemblies Typical Label Engraving Details

64825-2   Moulded Type M6 Link Assemblies Typical Label Engraving Details

52474-1   Moulded Type Link Assemblies Wire Terminations Coding and Looming Style Details 

56197-1   Wall Mounted CO2 Connection Box

113432-1   City Distribution Centres Signal Disconnection Box Label & Connection Details

115065-1   City Distribution Centres Pilot Isolation Boxes and Interconnector Pilot Boxes General Arrangement

115150-1   City Distribution Centres Pilot Isolating Boxes and Interconnector Pilot Boxes Label Details

115836-1   City Distribution Centres Using Motorised ACBs Signal Marshalling Box Connections

115837-1   City Distribution Centres Using Motorised ACBs Signal Marshalling Box General Arrangement and Details

115839-1   City Distribution Centres Using Motorised ACBs Pilot Marshalling Box Connections

116004-1   City Distribution Centres Pilot Isolating Boxes and Interconnector Pilot Boxes Connection Details

121156-1   City Distribution Substations with Optical Arc Flash Detection, Preferred layout of Pilot, DLAC and Fibre Equipment in Access Chambers

121949-1   Suburban Type Substations with 1500 kVA transformers Service Board General Arrangement and Wiring Diagram 

121950-1   Standard Services Boards City Distribution Substations Service Board with Substation Fan Control - General Arrangement and Wiring Diagram

121951-1   City Distribution Substations without Substation Fan Control Service Board - General Arrangement and Wiring Diagram

127332-1   Minimum Clearances for Chamber Type Substations Using Current Equipment

162655-1   Indoor Distribution Transformers – Mounting Details of Current Transformers and Earth Bar

169392-1   Standard Services Boards Suburban Type Substations Arrangement & Diagram with Drilling Details
                        (For use in suburban substations without active protection systems (1000 kVA or less transformers))

169393-1   Standard Services Boards Control Points Arrangement & Diagram with Drilling Details

169394-1   High Voltage Customer Substations Service Board General Arrangement and Wiring Diagram

178227-1   Type E LV Board Acceptable Combinations

178228-1   Type E LV Board Clearances, Pit Design and Construction

178229-1   Type E LV Board Supporting Steelwork General Arrangement

178230-1   Type E LV Board Auxiliary Cable Ladder Installation Detail

178237-1   E Type LV Board Merlin Gerin Masterpct Air Circuit Breakers External Connections

178238-1   Type E LV Board Summated MDI Wiring Diagram

178241-1   City and Suburban Distribution Substations Protection Panels Moulded Type Links and Label Details

187815-1   RMICB Substations with E Type LV Board Wall Mounted Transformer Protection Panel Drilling & Wiring

191085-1   Customer Chamber Substations HV Pit Construction & HV Switchgear Support Steelwork

191086-1   City & Suburban Distribution Substations Protection Relays Drilling Details

192908-1   Customer Chamber Type Substations Installation of Lucy Sabre VRN2a and VRN6a RMICB

192910-1   Customer Chamber Type Substations Installation of ABB Safelink 3 Way I & E Switch

192959-1   ABB Safelink for Chamber Substations Mounting Stand

204115-1   Vass Electrical Industries Standard Flanged End To Suit E Type LV Board

205769-1   Single Transformer LV Board General Arrangement (Typical)

205952-1   City Distribution Substations Free Standing Protection Cabinet Specification

205952-2   City Distribution Substations Free Standing protection Cabinet (With 650 x 850 Doors) specification

215882-1   Type E LV Board Reference Drawing List

224233-1   Two Transformer LV Board with Bus Section General Arrangement (Typical)

224407-1   Standard Surface Chamber Distribution Substation Single 750 or 1000KVA Transformer Layout 1

224408-1   Standard Surface Chamber Distribution Substation Single 750 or 1000KVA Transformer Layout 2

224420-1   Customer Chamber Type Substations Installation of ABB Safelink CFC RMI

224431-1   Two Transformer Distribution Substation with Double SAIF Fused Strip LV Board Summated MDI

227350-1   RMICB Substations with E Type LV Board AC Schematic with Optical Arc Flash Detection

227350-2   RMICB Substations with E Type LV Board Transformer DC Schematic with Optical Arc Flash Detection

227350-3   RMICB Substations with E Type LV Board Customer Overcurrent DC Schematic

227350-4   RMICB Substations with E Type LV Board DC Supply and Cable Looping Schematic

227350-5   RMICB Substations with E Type LV Board Fibre Looping & General Mounting Details

227351-1   RMICB Substations with E Type LV Board Transformer Wall Mounted Protection Panel with Optical Arc Flash Detection Style 1 Layout and Label Details Diagram

227351-2   RMICB Substations with E Type LV Board Transformer Protection Panel Style 1 Wiring Diagram

227351-3   RMICB Substations with E Type LV Board Transformer Wall Mounted Protection Panel Style 1 Cable Connection Diagram

227352-1   RMICB Substations with E Type LV Board Transformer Wall Mounted Protection Panel with Optical AFD Style 2 Layout and Label Details Diagram

227352-2   RMICB Substations with E Type LV Board Transformer Wall Mounted Protection Panel With Optical AFD Style 2 Wiring Diagram

227352-3   RMICB Substations with E Type LV Board Transformer Wall  Mounted Protection Panel  With Optical AFD Style 2 Cabling Connection Diagram

227353-1   RMICB Substations with E Type LV Board Customer Overcurrent Wall Mounted Protection Panel Layout and Label Details Diagram

227353-2   RMICB Substations with E Type LV Board Customer Overcurrent Wiring Diagram

227354-1   RMICB Substations with E Type LV Board Optical Arc Flash Detection Indication Panel Schematic, Drilling and Wiring Diagram

227355-1   RMICB Substations with E Type LV Board and Optical Arc Flash Detection Cabling Diagram

227355-2   RMICB Substations with E Type LV Board and Optical Arc Flash Detection Cable Schedule

227356-1   RMICB Substations With E Type LV Board Suburban Type Substation with 1500KVA Transformer Service Board  - General Arrangement and Wiring Diagram

227357-1   E Type LV Board Merlin Gerin Masterpac TP Air Circuit Breakers External Connections for AFD Distribution Substations

227358-1   RMICB Substations with E Type LV Board and Optical Arc Flash Detection SCADA Panel Wiring and Cabling Details

227358-2   RMICB Substations with E Type LV Board and Optical Arc Flash Detection SCADA Panel Layout Details Diagram

227360-2   Distribution Substation Supply Cabling and SCADA Schematic with Exposed LV Boards with OAFD

227363-1   Distribution Substation SCADA Panel Wiring & Cable Connections with Busbar Protection with OAFD

227363-2   Distribution Substation SCADA Panel Layout & Labels with Busbar Protection with OAFD

227389-1   City Distribution Substations with E Type LV Board, OAFD, & Customer OC No.1 & No.2 Protection Distribution Automation Control Panel Wiring and Cabling Diagram

227389-2   City Distribution Substations with E Type LV Board, OAFD, & Customer OC No.1  Protection Distribution Automation Control Panel Wiring and Cabling Diagram

228913-1   City Distribution Substations Ventilation Air Vane Switch Mark IV Manufacture and Installation Details

230701-1   Distribution Substations Fuse Strip Type LV Board Reference Drawing List

234377-1   Customer Chamber Type Substations Installation of Siemens 8DJH Switchgear

245776-4   Distribution Substation with RMICBS with Exposed Busbar LV Boards with Individual Tx OAFD Protection Supply Cabling & SCADA Schematic

245777-1   Distribution Substation with RMICBS with Exposed Busbar LV Boards with Free Standing Tx OAFD Protection Panels Layout & Label Details

245779-1   Distribution Substation with RMICBS with Exposed Busbar LV Boards with Individual Tx OAFD Protection SCADA Panel Wiring & Connections

245781-5   Distribution Substation with RMICBS with Individual Tx OAFD Protection with 4 Transformers Supply Cabling & SCADA Schematic

245781-6   Distribution Substation with RMICBS with Individual Tx OAFD Protection with 4 Transformers SCADA Panel Wiring & Connections

254134_1   City Distribution Substations Substation Fan Control Schematic

265238_1   LV Chamber Substation LV Fuseway Switchboard (WSP) 1600/400/400Amp General Arrangement

265238_2   LV Chamber Substation LV Fuseway Switchboard (WSP) 1600/400/400Amp Single Line

265238_3   LV Chamber Substation LV Fuseway Switchboard (WSP) 1600/400/400Amp Schematic

265239_1   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/400/400Amp General Arrangement

265239_2   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/400/400Amp Single Line

265239_3   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/400/400Amp Schematic

265240_1   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/800/400Amp General Arrangement

265240_2   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/800/400Amp Single Line

265240_3   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/800/400Amp Schematic

265241_1   LV Chamber Substation LV Fuseway Switchboard (WSP) 4x 400Amp General Arrangement

265241_2   LV Chamber Substation LV Fuseway Switchboard (WSP) 4x 400Amp Single Line

265241_3   LV Chamber Substation LV Fuseway Switchboard (WSP) 4x 400Amp Schematic

265242_1   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/400/400/400Amp General Arrangement

265242_2   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/400/400/400Amp Single Line

265242_3   LV Chamber Substation LV Fuseway Switchboard (WSP) 800/400/400/400Amp Schematic

265243_1   LV Chamber Substation LV Fuseway Switchboard (WSP) 5x 400Amp General Arrangement

265243_2   LV Chamber Substation LV Fuseway Switchboard (WSP) 5x 400Amp Single Line

265243_3   LV Chamber Substation LV Fuseway Switchboard (WSP) 5x 400Amp Schematic